!!################################ !!ALSA Information Script v 0.4.64 !!################################ !!Script ran on: Fri Jul 14 18:25:39 UTC 2017 !!Linux Distribution !!------------------ Debian GNU/Linux 7 \n \l PRETTY_NAME="Debian GNU/Linux 7 (wheezy)" NAME="Debian GNU/Linux" ID=debian HOME_URL="http://www.debian.org/" SUPPORT_URL="http://www.debian.org/support/" BUG_REPORT_URL="http://bugs.debian.org/" !!DMI Information !!--------------- Manufacturer: Intel Corporation Product Name: Merrifield Product Version: A1 Firmware Version: 466 !!Kernel Information !!------------------ Kernel release: 3.10.17-yocto-standard-r2 Operating System: GNU/Linux Architecture: i686 Processor: unknown SMP Enabled: Yes !!ALSA Version !!------------ Driver version: k3.10.17-yocto-standard-r2 Library version: 1.0.25 Utilities version: 1.0.25 !!Loaded ALSA modules !!------------------- !!Sound Servers on this system !!---------------------------- No sound servers found. !!Soundcards recognised by ALSA !!----------------------------- 0 [Loopback ]: Loopback - Loopback Loopback 1 !!PCI Soundcards installed in the system !!-------------------------------------- 00:0d.0 Multimedia audio controller: Intel Corporation Device 119a (rev 01) !!Advanced information - PCI Vendor/Device/Subsystem ID's !!------------------------------------------------------- 00:0d.0 0401: 8086:119a (rev 01) Control: I/O- Mem BusMaster- SpecCycle- MemWINV- VGASnoop- ParErr- Stepping- SERR- FastB2B- DisINTx- !!Modprobe options (Sound related) !!-------------------------------- snd_pcsp: index=-2 snd_usb_audio: index=-2 snd_atiixp_modem: index=-2 snd_intel8x0m: index=-2 snd_via82xx_modem: index=-2 !!Loaded sound module options !!--------------------------- !!ALSA Device nodes !!----------------- crw-rw---T 1 root audio 116, 6 Jul 14 18:04 /dev/snd/controlC0 crw-rw---T 1 root audio 116, 5 Jul 14 18:04 /dev/snd/pcmC0D0c crw-rw---T 1 root audio 116, 4 Jul 14 18:23 /dev/snd/pcmC0D0p crw-rw---T 1 root audio 116, 3 Jul 14 18:04 /dev/snd/pcmC0D1c crw-rw---T 1 root audio 116, 2 Jul 14 18:04 /dev/snd/pcmC0D1p crw-rw---T 1 root audio 116, 1 Jul 14 18:04 /dev/snd/seq crw-rw---T 1 root audio 116, 33 Jul 14 18:04 /dev/snd/timer !!Aplay/Arecord output !!-------------------- APLAY **** List of PLAYBACK Hardware Devices **** card 0: Loopback [Loopback], device 0: Loopback PCM [Loopback PCM] Subdevices: 8/8 Subdevice #0: subdevice #0 Subdevice #1: subdevice #1 Subdevice #2: subdevice #2 Subdevice #3: subdevice #3 Subdevice #4: subdevice #4 Subdevice #5: subdevice #5 Subdevice #6: subdevice #6 Subdevice #7: subdevice #7 card 0: Loopback [Loopback], device 1: Loopback PCM [Loopback PCM] Subdevices: 8/8 Subdevice #0: subdevice #0 Subdevice #1: subdevice #1 Subdevice #2: subdevice #2 Subdevice #3: subdevice #3 Subdevice #4: subdevice #4 Subdevice #5: subdevice #5 Subdevice #6: subdevice #6 Subdevice #7: subdevice #7 ARECORD **** List of CAPTURE Hardware Devices **** card 0: Loopback [Loopback], device 0: Loopback PCM [Loopback PCM] Subdevices: 8/8 Subdevice #0: subdevice #0 Subdevice #1: subdevice #1 Subdevice #2: subdevice #2 Subdevice #3: subdevice #3 Subdevice #4: subdevice #4 Subdevice #5: subdevice #5 Subdevice #6: subdevice #6 Subdevice #7: subdevice #7 card 0: Loopback [Loopback], device 1: Loopback PCM [Loopback PCM] Subdevices: 8/8 Subdevice #0: subdevice #0 Subdevice #1: subdevice #1 Subdevice #2: subdevice #2 Subdevice #3: subdevice #3 Subdevice #4: subdevice #4 Subdevice #5: subdevice #5 Subdevice #6: subdevice #6 Subdevice #7: subdevice #7 !!Amixer output !!------------- !!-------Mixer controls for card 0 [Loopback] Card hw:0 'Loopback'/'Loopback 1' Mixer name : 'Loopback Mixer' Components : '' Controls : 96 Simple ctrls : 0 !!Alsactl output !!-------------- --startcollapse-- state.Loopback { control.1 { iface PCM name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.2 { iface PCM name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.3 { iface PCM name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.4 { iface PCM name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.5 { iface PCM name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.6 { iface PCM name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.7 { iface PCM subdevice 1 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.8 { iface PCM subdevice 1 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.9 { iface PCM subdevice 1 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.10 { iface PCM subdevice 1 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.11 { iface PCM subdevice 1 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.12 { iface PCM subdevice 1 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.13 { iface PCM subdevice 2 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.14 { iface PCM subdevice 2 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.15 { iface PCM subdevice 2 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.16 { iface PCM subdevice 2 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.17 { iface PCM subdevice 2 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.18 { iface PCM subdevice 2 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.19 { iface PCM subdevice 3 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.20 { iface PCM subdevice 3 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.21 { iface PCM subdevice 3 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.22 { iface PCM subdevice 3 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.23 { iface PCM subdevice 3 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.24 { iface PCM subdevice 3 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.25 { iface PCM subdevice 4 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.26 { iface PCM subdevice 4 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.27 { iface PCM subdevice 4 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.28 { iface PCM subdevice 4 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.29 { iface PCM subdevice 4 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.30 { iface PCM subdevice 4 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.31 { iface PCM subdevice 5 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.32 { iface PCM subdevice 5 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.33 { iface PCM subdevice 5 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.34 { iface PCM subdevice 5 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.35 { iface PCM subdevice 5 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.36 { iface PCM subdevice 5 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.37 { iface PCM subdevice 6 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.38 { iface PCM subdevice 6 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.39 { iface PCM subdevice 6 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.40 { iface PCM subdevice 6 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.41 { iface PCM subdevice 6 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.42 { iface PCM subdevice 6 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.43 { iface PCM subdevice 7 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.44 { iface PCM subdevice 7 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.45 { iface PCM subdevice 7 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.46 { iface PCM subdevice 7 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.47 { iface PCM subdevice 7 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.48 { iface PCM subdevice 7 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.49 { iface PCM device 1 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.50 { iface PCM device 1 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.51 { iface PCM device 1 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.52 { iface PCM device 1 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.53 { iface PCM device 1 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.54 { iface PCM device 1 name 'PCM Slave Channels' value 1 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.55 { iface PCM device 1 subdevice 1 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.56 { iface PCM device 1 subdevice 1 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.57 { iface PCM device 1 subdevice 1 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.58 { iface PCM device 1 subdevice 1 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.59 { iface PCM device 1 subdevice 1 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.60 { iface PCM device 1 subdevice 1 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.61 { iface PCM device 1 subdevice 2 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.62 { iface PCM device 1 subdevice 2 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.63 { iface PCM device 1 subdevice 2 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.64 { iface PCM device 1 subdevice 2 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.65 { iface PCM device 1 subdevice 2 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.66 { iface PCM device 1 subdevice 2 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.67 { iface PCM device 1 subdevice 3 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.68 { iface PCM device 1 subdevice 3 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.69 { iface PCM device 1 subdevice 3 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.70 { iface PCM device 1 subdevice 3 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.71 { iface PCM device 1 subdevice 3 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.72 { iface PCM device 1 subdevice 3 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.73 { iface PCM device 1 subdevice 4 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.74 { iface PCM device 1 subdevice 4 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.75 { iface PCM device 1 subdevice 4 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.76 { iface PCM device 1 subdevice 4 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.77 { iface PCM device 1 subdevice 4 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.78 { iface PCM device 1 subdevice 4 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.79 { iface PCM device 1 subdevice 5 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.80 { iface PCM device 1 subdevice 5 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.81 { iface PCM device 1 subdevice 5 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.82 { iface PCM device 1 subdevice 5 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.83 { iface PCM device 1 subdevice 5 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.84 { iface PCM device 1 subdevice 5 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.85 { iface PCM device 1 subdevice 6 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.86 { iface PCM device 1 subdevice 6 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.87 { iface PCM device 1 subdevice 6 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.88 { iface PCM device 1 subdevice 6 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.89 { iface PCM device 1 subdevice 6 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.90 { iface PCM device 1 subdevice 6 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } control.91 { iface PCM device 1 subdevice 7 name 'PCM Rate Shift 100000' value 100000 comment { access 'read write' type INTEGER count 1 range '80000 - 120000 (step 1)' } } control.92 { iface PCM device 1 subdevice 7 name 'PCM Notify' value false comment { access 'read write' type BOOLEAN count 1 } } control.93 { iface PCM device 1 subdevice 7 name 'PCM Slave Active' value false comment { access read type BOOLEAN count 1 } } control.94 { iface PCM device 1 subdevice 7 name 'PCM Slave Format' value 2 comment { access read type INTEGER count 1 range '0 - 49 (step 1)' } } control.95 { iface PCM device 1 subdevice 7 name 'PCM Slave Rate' value 48000 comment { access read type INTEGER count 1 range '0 - 192000 (step 1)' } } control.96 { iface PCM device 1 subdevice 7 name 'PCM Slave Channels' value 2 comment { access read type INTEGER count 1 range '1 - 1024 (step 1)' } } } --endcollapse-- !!All Loaded Modules !!------------------ Module ftdi_sio uvcvideo videobuf2_vmalloc videobuf2_memops videobuf2_core usb_f_acm u_serial g_multi libcomposite bcm_bt_lpm bcm4334x !!ALSA/HDA dmesg !!-------------- [ 1.596079] intel_scu_fw_update rpmsg11: Allocating rpmsg_instance [ 1.600976] usbcore: registered new interface driver snd-usb-audio [ 1.601595] snd_intel_sst: INFO: ******** SST DRIVER loading.. Ver: 3.0.8 [ 1.602236] snd_intel_sst: Got drv data max stream 25 [ 1.604821] snd_intel_sst: intel_sst_probe successfully done! [ 1.605057] oprofile: using NMI interrupt. -- [ 1.609546] Bridge firewalling registered [ 1.609620] snd_intel_sst: runtime_idle called [ 1.609639] snd_intel_sst: runtime_suspend called [ 1.610316] Bluetooth: RFCOMM TTY layer initialized -- [ 1.670508] dpcm dummy is not supported according to cmdline [ 1.670586] ALSA device list: [ 1.670605] #0: Loopback 1